  • 產品名稱:Allograft Inflammatory Factor 1 (AIF1) Antibody Pair

  • 產品型號:abx370492
  • 產品廠商:abbexa
  • 產品文檔:
你添加了1件商品 查看購物車
簡單介紹:
Allograft Inflammatory Factor 1 (AIF1) Antibody Pair
詳情介紹:
Allograft Inflammatory Factor 1 (AIF1) Antibody Pair for use in Sandwich ELISA assay development. This antibody pair contains:

Component 5 × 96 tests 10 × 96 tests
Capture Antibody200 μg 400 μg
Biotin-Conjugated Detection Antibody 50 μg 100 μg
Standard 2 μg 10 μg

Please note that quantities and concentrations may change between different batches.

It is recommended to use this antibody pair with abx098958 Antibody Pair Support Kit (Sandwich Method).

Target Allograft Inflammatory Factor 1 (AIF1)
Reactivity Human
Tested Applications ELISA
Recommended dilutions Dilute the Capture Antibody 125-fold with Coating Buffer.
Dilute the Biotin-Conjugated Detection Antibody 200-fold with Detection Antibody Diluent.

Optimal dilutions/concentrations should be determined by the end user.
Form Liquid (Capture Antibody and Detection Antibody)
Reconstitution Reconstitute the standard with Standard Diluent. The volume, and therefore standard concentration, should be determined by the end user.
Storage Aliquot and store at -20°C. Avoid repeated freeze/thaw cycles.
Buffer The Capture and Detection Antibody both contain 0.1% sodium azide.
Standard Form Lyophilized
Assay Type Sandwich
Capture Antibody Conjugation Unconjugated
Detection Antibody Conjugation Biotin
Concentration Capture Antibody: 0.5 mg/ml
Biotin-Conjugated Detection Antibody: 0.2 mg/ml
Availability Please enquire.
Note This product is for research use only.
Directions for use Bring all components to room temperature (18-25°C) and briefly spin or centrifuge the vials before use. Working solutions should be prepared and used immediately.

Recommended Procedure:

  • Dilute the Capture Antibody to working concentration using Coating Buffer. Immediately coat the 96-well plate with diluted Capture Antibody (100 μl per well). Seal the plate and incubate at 4 °C overnight or at 37 °C for 2 hours
  • Aspirate the wells and wash with Wash Buffer (350 μl per well) and allow to soak for 1-2 min. Remove the liquid by inverting and tapping the plate on to absorbent paper.
  • Block the plate with Blocking Buffer (200 μl per well) at 37 °C for 1.5 hours.
  • Repeat the aspiration/wash process in Step 2.
  • Add 100 μl of standards or sample into the appropriate wells. Cover with a plate sealer and incubate at 37 °C for 1 hour.
  • Repeat the aspiration/wash process in Step 2.
  • Add appropriately diluted Biotin-Conjugated Detection Antibody (100 μl per well). Cover the plate with a new plate sealer and incubate at 37 °C for 1 hour.
  • Repeat the aspiration/wash process in Step 2.
  • Add appropriately diluted Streptavidin HRP (100 μl per well). Cover the plate with a new plate sealer and incubate at 37 °C for 30 min.
  • Repeat the aspiration/wash process in Step 2.
  • Add Substrate Solution (90 μl per well). Cover the plate with a new plate sealer and incubate at 37 °C for 10-20 min. Keep the plate in the dark and avoid exposure to light.
  • Add Stop Solution (50 μl per well). Tap the side of the plate to ensure thorough mixing.
  • Measure the absorbance immediately using a microplate reader set at 450 nm.